Incremental
• Standard Size 58 Mounting (58 mm Diameter)
• Up to 30,000 CPR
• 80 lb Max. Axial and Radial Shaft Loading
• High Temperature Option (100° C)
• IP67 Sealing Available
Incremental
·One-or two-channel versions
·ATEX- certification for intrinsically safe devices
·High-resolution, unbreakable code disc
·Standard industrial plugs
·Ingress protection NEMA 4X, IP67
·Available with housing made of nickel or stainless steel
Incremental
· One-or two-channel versions
· Double-sealed housing
· High-resolution, unbreakable code disc
· Industrial plugs
· Ingress protection NEMA 4X,6 / IP66, IP67
· Robust housing made of diecast aluminium
· Also available as stainless steel varian·
Absolute
• Single-turn and multi-turn: Resolution up to 28 bits
• Wear-free electronic multi-turn: contact-less and battery-less, energy independent
• 300 N axial and radial load
• 200 g shock-resistance/ 20 g vibration-resistance
• suitable for use with high-pressure cleaners: Ingress protection up to IP 69K
Absolute
• Single-turn and multi-turn absolute encoders
• Broad temperature range: -40 to +100°C
• Resolution: up to 34 bits (22 bits in single-turn,
12 bits in multi-turn, depending upon interface)
• Compact construction: 50 mm long
• High EMC compatibility
• Various bus connections: SSI, BiSS, Profibus,
Standard Operating Characteristics | |
---|---|
Horizontal Field of view:2°,3°,4° Model:HNS02LW30S1 Product TemperatureLimit:Minimum 330°C (630°F) Vertical Field of View:18°,30°,45° Operating voltage:110 VAC or 24 VDC |
Environmental | |
---|---|
Operating ambient temperature: -10°Cto 45°C/without cooling -2°Cto 65°C/(20°C) water-cooling
|
Standard Operating Characteristics | |
---|---|
Measuring range:0.2-25M, Measuring accuracy:+/-3mm(0.2-25M) Repeatability:+/-5mm |
Environmental | |
---|---|
Operating ambient temperature: -10°C (14°F) to +50°C (122°F)
|
Standard Operating Characteristics | |
---|---|
Measuring range:0.05-150M, Measuring accuracy:+/-1.5mm(0.2-25M) Repeatability:+/-0.4mm |
Environmental | |
---|---|
Operating ambient temperature: -10°C (14°F) to +50°C (122°F) |
Standard Operating Characteristics | |
---|---|
Typical decetion:10mm Rod at 350°C from 2 meters 50mm Bar at 350°C from 4 meters. Min product Temperature:300°C Scanning angle:1°*15°,Options:2°*20°,3°*35° Operating voltage:110 VAC or 24 VDC |
Environmental | |
---|---|
Operating ambient temperature: -20 °C to 60 °C/air-cooling. +2 °C to 70 °C /water-cooling
|
Standard Operating Characteristics | |
---|---|
Temperature range:300°C-1100°C, Model:HND310w1s1 Options:250°C-1100°C Scanning angle:1°*25°,Options:2°,4° Operating voltage:110 VAC or 24 VDC |
Environmental | |
---|---|
Operating ambient temperature: -20 °C to 60 °C (-40°F to 140°F)w/air-cooling. +2 °C to 80 °C (36°F to 176°F)w/water-cooling
|
Standard Operating Characteristics | |
---|---|
Temperature range:300°C-1100°C, Options:250°C-1100°C Scanning angle:1/2°*25°,precision slit Lens Operating voltage:80-240VAC or 24 VDC |
Environmental | |
---|---|
Operating ambient temperature: -20 °C to 60 °C (-40°F to 140°F) |
Standard Operating Characteristics | |
---|---|
I.R. Threshold settings:Selector switch selectable in 50°C steps Scanning angle:2°,4° Operating voltage:110 VAC or 24 VDC |
Environmental | |
---|---|
Operating ambient temperature: +2 °C to 70 °C (20°F)/water-cooling +2 °C to 90 °C (5°F)/water-cooling
|